Hitachi KP-FR200PCL 2.01 Megapixel Raw Data Output Power Over Camera Link Industrial Camera
![]()
Industrial Video System & Broadcast
Hitachi : KP-FR200PCL
Description
The Hitachi KPFR200PCL is CameraLink output system progressive scan RAW data output color CCD camera with a 1/1.8-inch size CCD which adopted the RGB primary color filter and a full fame
shutter. The image of 1628 (H) x 1236 (V) is output in RAW data at 15 frames per second. The square format picture elements provide suitability for image processing applications.
The Hitachi KP FR200PCL 1/1.8-inch 2,000,000 pixels square lattice progressive scan CCD and the RGB primary color
mosaic filter achieve a high resolution and high color fidelity of 1628 (H) x 1236 (V) (UXGA). The camera has small SDR connector for digital outputs. Therefore, the camera has the realization of small-sized shape of 29 (W) x 29 (H) x 29 (D) mm. Power supply of is input via CameraLink cable.
Specifications
| Imaging device | 1/1.8-inch interline CCD |
| Total pixels | 1688 (H)x1248 (V) |
| Effective pixels | 1628 (H)x1236 (V) |
| Pixel size | 4.4 µm (H)x4.4 µm (V)(square lattice) |
| Color filter | RGB primary color mosaic filter |
| Sensing area | 7.16 mm (H)x5.44 mm (V) |
| Scanning system | Progressive |
| Aspect ratio | 4 : 3 |
| Frame rate | 15 frames per second (full pixel readout) |
| Horizontal drive frequency | 36.0000 MHz |
| Scanning frequency | Horizontal: 18.75 kHz, Vertical: 14.97 Hz |
| Sync system | Internal |
| Lens mount | C mount (Flange focal distance =17.526 mm) |
| Video output | Digital output (CameraLink) |
| Base configuration | 36.0000 MHz (Note: maximum cable length is 10 m) |
| Output image size | 1628 (H)x1236 (V) (full pixel readout) |
| Resolution | Horizontal / Vertical: 1200 TV lines |
| Sensitivity | 2000 lx, F8, 3200 K |
| Minimum illumination | 5.0 lx (F1.4, MAX GAIN) |
| Signal noise to ratio | 50 dB |
| Electric shutter | OFF, 1/15, 1/60, 1/125, 1/250, 1/1000, 1/2000, 1/10000, 1/50000 second; OFF is normal exposure (frame rate) or changeable by variable shutter (minimum 1/100000 second) |
| Gamma | γ = 1 |
| Frame on demand | Mode: (A) Fixed shutter mode (8 steps or variable); (B) ONE trigger mode; (C) VD reset mode |
| Trigger input | CameraLink (CC1) *When Reset control mode CC1 and CC2 are used |
| Partial scan | Selectable start position and height of picture grabbing in 1H step. |
| Power supply voltage | 12 ± 1 VDC |
| Current consumption | Approx. 170 mA (approx. 2.1 W) |
| Ambient temperature | Performance: 0 to 40 °C ( 32 to 104 °F), less than 90 % RH (without dew condensation) |
| Operation | 10 to 50 °C ( 14 to 122 °F), less than 90 % RH (without dew condensation) |
| Storage | -20 to 60 °C (-4 to 140 °F), less than 70 % RH (without dew condensation) |
| Vibration endurance | 98 m/s2 (Acceleration: constant) 10 to 200 Hz, sweep: 10 minutes, XYZ 30 minutes |
| Shock endurance | 686 m/s2 (Drop test, once each top, bottom, left and right) |
| External dimensions | 29 (W)x29 (W)x29 (D) mm (Not including protrusions) |
| Mass | Approx. 50 g |