Two (2) Output Power Supply/Charger w/Fire Alarm Disconnect - 12VDC or 24VDC @ 2 amp max

Contact us for lowest price (800) 284-2288 , (858) 565-1101 Call Now [email protected]

The Altronix eFlow3N is a power supply/charger that converts a 120VAC, 60Hz input into a single 12VDC or 24VDC power-limited output.

 

Available Configurations Include:

EFLOW3NX  Two (2) Output Power Supply/Charger w/Fire Alarm Disconnect - 12VDC or 24VDC @ 2 amp max, additional separate 1 amp aux. Class 2 rated power-limited output, AC & battery

EFLOW4N  Two (2) Output Power Supply/Charger w/Fire Alarm Disconnect - 12VDC or 24VDC @ 4 amp max, additional separate 1 amp aux. Class 2 rated power-limited output, AC & battery

EFLOW4NX  Two (2) Output Power Supply/Charger w/Fire Alarm Disconnect - 12VDC or 24VDC @ 4 amp max, additional separate 1 amp aux. Class 2 rated power-limited output, AC & battery

EFLOW6N  Two (2) Output Power Supply/Charger w/Fire Alarm Disconnect - 12VDC or 24VDC @ 6 amp max, additional separate 1 amp aux. Class 2 rated power-limited output, AC & battery

EFLOW6NX  Two (2) Output Power Supply/Charger w/Fire Alarm Disconnect - 12VDC or 24VDC @ 6 amp max, additional separate 1 amp aux. Class 2 rated power-limited output, AC & battery

 

EFLOW3N features include:

  • 120VAC, 60Hz, 3.5 amp.

  • Input fuse: 5A/250V.

  • 12VDC or 24VDC selectable output.

  • 12VDC or 24VDC @ 2.0 amp supply current.

  • Power-limited output.

  • Auxiliary Power-Limited output rated @ 1 amp (unswitched).

  • Over Voltage Protection.

  • Built-in charger for sealed lead acid or gel type batteries.

  • Maximum charge current 1.54 amp.

  • Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption.

  • Supervision:

  • AC fail supervision (form "C" contacts).

  • Battery fail & presence supervision (form "C" contacts).

  • Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units(depending on the power supply). Prevents deep battery discharge.

  • Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open (NO) or normally closed (NC) trigger.

  • Operating temperature: 0° C to 49° C ambient.

  • BTU/Hr.:

  • 12VDC: 12.28BTU/Hr.

  • 24VDC: 24.57BTU/Hr.

  • System AC input VA requirement: 420VA.

  • Green AC Power LED indicates 120VAC present.

  • AC input, DC output and Battery LED indicators.

  • Additional Features:

  • Short circuit and overload protection.

  • Unit is complete with power supply, enclosure, battery leads and cam lock.