Two (2) Output Power Supply/Charger w/Fire Alarm Disconnect - 12VDC @ 10 amp max |
|
|
The Altronix eFlow102N is a power supply/charger that converts a 120VAC 60Hz input into a single 12VDC output with a total of 10 amps max. The unit includes a unswitched aux. output. It also offers a suite of features that includes fire alarm disconnect, over voltage protection, and low power disconnect which prevents deep discharge of stand-by batteries.
Available Configurations Include:
EFLOW102NX | Two (2) Output Power Supply/Charger w/Fire Alarm Disconnect - 12VDC @ 10 amp max, additional separate 1 amp aux. Class 2 rated power-limited output, AC & battery monitoring, Low power shutdown, Over voltage protection (OVP), encl. 15.5”H x 12”W x 4.5”D accomodates up to (2) 12VDC/12AH batteries, 115VAC input, UL Listed (UL294/UL603/UL1481), cUL Listed (ULC-S318-96). CSFM, CE Approved. |
EFLOW104N | Two (2) Output Power Supply/Charger w/Fire Alarm Disconnect - 24VDC @ 10 amp max, additional separate 1 amp aux. Class 2 rated power-limited output, AC & battery monitoring, Low power shutdown, Over voltage protection (OVP), encl. 13.5”H x 13”W x 3.25”D accomodates up to (2) 12VDC/7AH batteries, 115VAC input, UL Listed (UL294/UL603/UL1481), cUL Listed (ULC-S318-96). CSFM, CE Approved. |
EFLOW104NX | Two (2) Output Power Supply/Charger w/Fire Alarm Disconnect - 24VDC @ 10 amp max, additional separate 1 amp aux. Class 2 rated power-limited output, AC & battery monitoring, Low power shutdown, Over voltage protection (OVP), encl. 15.5”H x 12”W x 4.5”D accomodates up to (2) 12VDC/12AH batteries, 115VAC input, UL Listed (UL294/UL603/UL1481), cUL Listed (ULC-S318-96). CSFM, CE Approved. |
EFLOW102N features include:
120VAC, 60Hz, 3.5 amp.
Input fuse: 5A/250V.
12VDC @ 10.0 amp supply current.
Auxiliary Power-Limited output rated @ 1 amp (unswitched).
Over Voltage Protection.
Built-in charger for sealed lead acid or gel type batteries.
Maximum charge current 1.54 amp.
Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption.
AC fail supervision (form "C" contacts).
Battery fail & presence supervision (form "C" contacts).
Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% (depending on the power supply). Prevents deep battery discharge.
Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open (NO) or normally closed (NC) trigger.
Operating temperature: 0° C to 49° C ambient.
BTU/Hr.: 61.42 BTU/Hr.
System AC input VA requirement: 420VA.
Green AC Power LED indicates 120VAC present.
AC input, DC output and Battery LED indicators.
Additional Features:
Short circuit and overload protection.
Unit is complete with power supply, enclosure, battery leads and cam lock.
eflow102n.pdf | Datasheet |
Call Now: 1-800-284-2288 |
|||||
Email Us: sales@avsupply |
|||||
|