The Altronix eFlow3N4D is a power supply/charger that converts a 120VAC, 60Hz input into four (4) PTC protected 12VDC or 24VDC power-limited outputs.

 

Available Configurations Include:

EFLOW3NX4D Power Supply/Charger w/Fire Alarm Disconnect - 12VDC or 24VDC @ 2 amp max. Four (4) PTC power-limited outputs and one (1) aux. power output, AC & battery monitoring, Low battery cutoff, Over voltage protection, encl. 15.5”H x 12”W x 4.5”D accomodates up to (2) 12VDC/12AH batteries, 115VAC input, UL Listed (UL294/UL603/UL1481), cUL Listed (ULC-S318-96). CSFM, CE Approved.
EFLOW4N8D Power Supply/Charger w/Fire Alarm Disconnect - 12VDC or 24VDC @ 4 amp max. Eight (8) PTC power-limited outputs and one (1) aux. power output, AC & battery monitoring, Low battery cutoff, Over voltage protection, encl. 13.5”H x 13”W x 3.25”D accomodates up to (2) 12VDC/7AH batteries, 115VAC input, UL Listed (UL294/UL603/UL1481), cUL Listed (ULC-S318-96). CSFM, CE Approved.
EFLOW4NX8D Power Supply/Charger w/Fire Alarm Disconnect - 12VDC or 24VDC @ 4 amp max. Eight (8) PTC power-limited outputs and one (1) aux. power output, AC & battery monitoring, Low battery cutoff, Over voltage protection, encl. 15.5”H x 12”W x 4.5”D accomodates up to (2) 12VDC/12AH batteries, 115VAC input, UL Listed (UL294/UL603/UL1481), cUL Listed (ULC-S318-96). CSFM, CE Approved.

EFLOW3N4D features include:

  • 120VAC, 60Hz, 3.5 amp.
  • Input fuse: 5A/250V.
  • Four (4) PTC protected Class 2 Rated power-limited outputs.
  • 12VDC or 24VDC selectable output.
  • 12VDC or 24VDC @ 2.0 amp supply current.
  • Outputs are rated @ 2 amp.
  • Auxiliary power-limited output rated @ 1 amp (unswitched).
  • Over Voltage Protection
  • Maximum charge current 1.54 amp.
  • Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption.
  • AC fail supervision (form "C" contacts).
  • Battery fail & presence supervision (form "C" contacts).
  • Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open (NO) or normally closed (NC) trigger.
  • Operating temperature: 0° C to 49° C ambient.
  • BTU/Hr.:
  • 12VDC: 12.28 BTU/Hr.
  • 24VDC: 24.57 BTU/Hr.
  • System AC input VA requirement: 420VA.
  • Green AC Power LED indicates 120VAC present.
  • AC input, DC output and Battery LED indicators.
  • Short circuit and overload protection.
  • Unit is complete with power supply, enclosure, battery leads and cam lock.