Canon : JCS-HR5U
Description
The Canon Medical JCS-HR5U camera represents an important advancement in clinical microscopy imaging applications. The ultra-compact, full HD video camera features both HDMI and SuperSpeed USB image outputs for simultaneous, real-time live viewing from a monitor, plus high-res image capture to a computer. The JCS-HR5U is optimal for color documentation systems integration in the fields of bio imaging, scientific imaging and live tissue imaging.
The 1.75” x 1.75” x 3” camera integrates easily with any clinical microscope using a C-mount lens adapter. Incorporating the latest CMOS sensor technology and advanced image processing provides exceptional sensitivity and color accuracy for a real-time video solution.
Features
- HDMI 1080p / 1080i output at 59.94Hz
- USB 3.0 1080p output at 59.94 fps maximum
- Simultaneous live view and USB output
- F10 sensitivity rivals three-chip camera performance
- 1/2.8″ progressive-scan color CMOS sensor
- 12-color channel matrix adjustment
- Gamma correction
- Ultra-compact (approx 1.75″ x 1.75″ x 3″) one-piece system
- 5 User-programmable settings files
- Integrates with PC for image capture and streaming (not provided)
- C-mount lens mount
- Digital crosshair lines
- Camera control via UVC 1.1
Specifications
Performance Specifications
| Image Sensor | 1/2.8 inch color CMOS sensor (progressive scan, rolling shutter) |
|---|---|
| Lens Mount | C mount |
| Image output | HDMI 1.4a 4:4:4 : 1920 x 1080 / 59.94Hz USB 3.0 (UVC1.1 compliant YUV4:2:2 : USB 3.1 Gen 1) 1920 x 1080 / 59.94fps (USB 3.0 mode theoretical maximum) 1920 x 1080 / 10fps (USB 2.0 mode theoretical maximum) |
| Sensitivity | F10 standard (2000lx, 3100K, gain OFF, gamma OFF, 59.94Hz); F11 standard (2000lx, 3100K, gain OFF, gamma OFF, 50Hz) |
| Minimum illumination | 4lx standard (F1.4, 3100K, gain +20dB, gamma OFF, 59.94Hz) 3.3lx standard (F1.4, 3100K, gain +20dB, gamma OFF, 50Hz) |
| Power requirements | DC12V± 10%, power consumption approx. 4.5W |
| Environmental | 0°C ~ + 40°C (32°F ~ +104°F) operating -20°C ~ + 60°C (-4°F ~ +140°F) non-operating Humidity 90° or less non-condensing |
| Gain | AUTO / MANUAL : 0 ~ 20dB / OFF |
| White balance | AWB (Automatic White Balance) / MANUAL |
| Shutter | AUTO / MANUAL (OFF ~ 1/10000s) |
| Image optimization function | MATRIX color correction (12 colors), gamma correction, detail gain, master pedestal chroma gain setting, knee correction |
| Camera Control | UVC 1.1 |
| Special function | Flip / mirror, digital crosshair lines |
Resources & Documents
| vsd-ds-jcs-hr5u.pdf | datasheet |