0.300 x telecentric lens with built-in coaxial illumination for detectors up to 1″
By: Opto Engineering
Optical Imaging Technologies for Machine Vision

Opto Engineering : RT-TCL0300-FU
Description
Working distance: distance between the front end of the mechanics and the object. Set this distance within ±3% of the nominal value for maximum resolution and minimum distortion. Working f-number (wf/N): the real f-number of a lens in operating conditions. Measured from the front end of the mechanics to the camera flange.
Specifications
Main optical specifications | |||||||||||
Magnification | (x) | 0.300 | |||||||||
Image circle diameter | (mm) | 16.0 | |||||||||
Max sensor size | 1″ |
Object field of view | |||||||||||
1/2.5” | (mm × mm) | 19.00 x 14.27 | |||||||||
1/1.8” | (mm × mm) | 23.77 x 17.77 | |||||||||
2/3” | (mm × mm) | 28.33 x 23.63 | |||||||||
1″ | (mm × mm) | 47.30 x 25.03 | |||||||||
1.1″ | (mm × mm) | 47.20 x 34.57 |
Advanced optical specifications | |||||||||||
Working distance (1) | (mm) | 167.0 | |||||||||
Working ƒ/N (2) | 12-60 | ||||||||||
Distortion | (%) | < 0.01 | |||||||||
Depth of field | (mm) | 5.00 | |||||||||
Resolution | (μm) | 26.8 |
Mechanical specifications | |||||||||||
Mount | C | ||||||||||
Phase adjustment | No | ||||||||||
Length (3) | (mm) | 338.2 | |||||||||
Front diameter | (mm) | 68.0 | |||||||||
Mass | (g) | 819 |