0.600 x telecentric lens with built-in coaxial illumination for detectors up to 1″
By: Opto Engineering
Optical Imaging Technologies for Machine Vision

Opto Engineering : RT-TCL0600-FU
Description
Working distance: distance between the front end of the mechanics and the object. Set this distance within ±3% of the nominal value for maximum resolution and minimum distortion. Working f-number (wf/N): the real f-number of a lens in operating conditions. Measured from the front end of the mechanics to the camera flange.
Specifications
Main optical specifications | |||||||||||
Magnification | (x) | 0.600 | |||||||||
Image circle diameter | (mm) | 16.0 | |||||||||
Max sensor size | 1″ |
Object field of view | |||||||||||
1/2.5” | (mm × mm) | 9.50 x 7.13 | |||||||||
1/1.8” | (mm × mm) | 11.88 x 8.88 | |||||||||
2/3” | (mm × mm) | 14.17 x 11.82 | |||||||||
1″ | (mm × mm) | 23.65 x 12.52 | |||||||||
1.1″ | (mm × mm) | 23.60 x 17.28 |
Advanced optical specifications | |||||||||||
Working distance (1) | (mm) | 78.5 | |||||||||
Working ƒ/N (2) | 12-60 | ||||||||||
Distortion | (%) | < 0.04 | |||||||||
Depth of field | (mm) | 1.20 | |||||||||
Resolution | (μm) | 13.4 |
Mechanical specifications | |||||||||||
Mount | C | ||||||||||
Phase adjustment | No | ||||||||||
Length (3) | (mm) | 228.5 | |||||||||
Front diameter | (mm) | 44.0 | |||||||||
Mass | (g) | 428 |