Supplying Wholesale Markets • OEM Solutions • Extensive Product Range

Frame Synchronizer & TBC

By: FOR-A

FOR-A Hanabi Audio Video Equipment

Video and Audio Systems for Broadcast Post-Production, and Professional Video

FOR-A : FA-125

Description

The FOR-A FA 125 is a low cost Time Base Corrector / Frame Synchronizer. The FA125 corrects by up to one full frame the time base error/ phase shift problems that can occur during recording/playback of composite signals when using heterodyne process VTRs.

Features

Analog composite video input/output compatible. (Y/C is also supported.)
Full frame memory to prevent picture field inversion during processing.
10-bit digital decode / encode to ensure stable signals without bit dropout.

Specifications

42:2 component internal signal processing.
Video Format NTSC
Video Input Analog composite = 1.0 Vp-p, 75Ω BNC x 1; Y/C Y = 1.0 Vp-p; C = 0.286 Vp-p; 75Ω 4-pin S-connector x 1
Genlock Input BB = 0.429 Vp-p; 75Ω BNC x 1, loop-through (Terminate with 75Ω terminator, if unused.)
Video Output Analog composite = 1.0 Vp-p, 75Ω BNC x 2; Y = 1.0 Vp-p; C = 0.286 Vp-p; 75Ω 4-pin S-connector x 1
Signal Processing 4:2:2 component
Correction Range 2 fields (field inversion prevented)
Sampling Frequency Y = 13.5 MHz; C = 6.75 MHz
Quantization 10-bit
Frequency Response 100 kHz to 4.2 MHz = ±0.5 dB, 4.2 MHz to 5.0 MHz = -1.0 dB to 0 dB, roll off above 5.0 MHz
S/N Ratio 56 dB (no quantization noise)
DG/DP 2% / 2°
K-Factor (2T Pulse) Less than 1%
H/V Tilt Less than 1%
Residual Jitter Y = ±15 ns; C = ±2°
Process Control Video Level = -3 dB to 3 dB; Chroma Level = -3 dB to 3 dB; Setup Level = -15 IRE to 15 IRE; Chroma Phase = -30° to 30°
Genlock Phase Control H Phase = -2 ®s to 2 ®s / SC Phase = -180° to 180°
Temperature 10°C to 40°C
Humidity 30% to 90% (no condensation)
Power 100 V AC to 240 V AC ±10%, 50/60 Hz
Consumption 29 VA (19 W) at 100 V AC, 37 VA (20 W) at 220 V AC
Dimensions 212 (W) x 44 (H) x 350 (D) mm
Weight 2.5 kg
Accessories Operation manual, AC cord